Jack Springford | 20th November 2026
Fire strategies and fire risk assessments are closely connected, but they serve different purposes. Understanding that difference helps building owners, employers and managing agents commission the right advice and make better decisions about fire safety.
A fire strategy explains how fire safety is intended to be achieved and maintained in a building. A fire risk assessment examines the risks presented by the premises and identifies the precautions needed to protect people.
Both need to reflect how the building is actually used. Neither should be treated as a document that is completed once and then forgotten.
A fire strategy establishes the building’s fire safety objectives and explains how its design, protection measures and management arrangements work together to achieve them. Depending on the building, it may address:
Escape routes and evacuation arrangements.
Compartmentation, fire doors and structural fire resistance.
Fire detection, alarms, smoke control and suppression systems.
External fire spread and access and facilities for firefighters.
Occupancy limits, staffing requirements and management responsibilities.
Assumptions, limitations and any departures from recognised guidance.
An evacuation strategy is therefore one part of the wider fire strategy. A useful strategy explains why particular measures are necessary, how they interact and what must remain in place for the overall approach to work.
Life safety is central, but a strategy can also address agreed objectives such as property protection, business continuity and protection of heritage assets.
A fire risk assessment, often shortened to FRA, considers the fire hazards, the people who could be harmed and whether the existing precautions adequately control the risks.
It examines the premises as they are used and managed, including ignition sources, combustible storage, escape routes, fire protection systems, maintenance, staff training and evacuation arrangements.
Its findings should identify necessary improvements and provide a clear basis for prioritising action. Completing the report is only part of the process: the findings need to be acted upon, and the assessment kept under review.
The relationship works in both directions. The strategy informs the FRA, while findings from the FRA may show that the strategy needs reviewing.
For a new building, fire strategy work should begin early enough to influence the design. Decisions about stairs, escape routes, compartmentation and firefighting access can be difficult and expensive to change once the design is advanced.
The strategy should develop alongside the project and be updated to reflect the completed building and its operational requirements.
A strategy may also need to be prepared or reviewed when:
A building is extended, converted or substantially refurbished.
Its use, occupancy or evacuation arrangements change.
Fire protection systems are altered.
An FRA identifies uncertainty about the building’s fire safety arrangements.
Original information is missing, incomplete or inconsistent with the building.
For existing premises, an in-occupation fire strategy, sometimes called a retrospective fire strategy, can help establish how fire safety is achieved now. It should be based on available evidence, site conditions and actual management arrangements, with uncertainties clearly identified.
Missing documentation does not automatically mean every small, straightforward premises needs an extensive standalone strategy report. The response should be proportionate to the building’s risks and complexity. Nor should an outstanding strategy delay necessary action on an immediate fire safety concern.
A reliable strategy gives the assessor essential context. For example, it may explain why a particular alarm arrangement was selected, which walls form fire compartments, what a smoke control system is intended to achieve, or what staffing arrangements underpin assisted evacuation.
Without that information, the assessor may need further evidence or specialist investigation before reaching a sound conclusion.
Consider a care setting operating progressive horizontal evacuation. The strategy should explain the compartmentation and staff response on which that approach depends. The FRA then considers whether those provisions remain suitable in practice, taking account of residents’ needs, staff availability, training and the condition of the building.
A good strategy can therefore help the assessor:
Identify critical systems and management dependencies.
Understand and evaluate the reasoning behind unusual arrangements.
Recognise alterations that may have undermined the original approach.
Make more consistent, proportionate recommendations.
Explain why particular deficiencies matter.
A strategy is evidence to assess, not proof that the building is safe. The assessor still needs to consider whether it is accurate, current and supported by what is found on site.
The person undertaking an FRA needs competence appropriate to the premises and the assessment’s scope. A Responsible Person may assess straightforward premises themselves where they have the necessary competence; more complex premises require greater expertise. Appointing an assessor does not remove the Responsible Person’s duties.
BS 8674:2025 provides a framework for individual fire risk assessor competence, with Foundation, Intermediate and Advanced levels. Relevant experience, qualifications and independently assessed competence should be considered when selecting an assessor.
Fire strategies should be prepared by professionals who can demonstrate competence in the building type and the approach proposed. Complex strategies and engineered solutions require appropriate fire engineering expertise.
Competence in undertaking FRAs does not automatically establish competence in fire strategy design. Equally, experience in design does not automatically demonstrate competence in assessing occupied premises.
Clients should look beyond job titles and ask about relevant projects, qualifications, technical capability, review arrangements and professional indemnity cover.
The following overview focuses on England. The Fire Safety Order also applies in Wales, but building regulations guidance and additional requirements differ across the UK.
Article 9 of the Regulatory Reform (Fire Safety) Order 2005, as amended, requires a suitable and sufficient FRA for premises within its scope. It must be reviewed regularly and particularly where there is reason to doubt its validity or following significant changes.
Other relevant legislation includes:
The Fire Safety Act 2021, which clarified the Fire Safety Order’s application to the structure, external walls and flat entrance doors of buildings containing two or more domestic premises.
The Fire Safety (England) Regulations 2022, which introduce additional duties for relevant residential buildings.
The Building Safety Act 2022, including amendments strengthening requirements to record and share fire safety information.
Assessment guidance includes PAS 79-1:2020 for premises other than housing and BS 9792:2025 for housing, alongside relevant government and sector-specific guidance. The guidance selected must suit the premises and their occupants.
For building work in England, the Building Regulations 2010, particularly Part B, provide the principal fire safety requirements. Relevant guidance includes:
Approved Document B.
BS 9991 for residential buildings within its scope.
BS 9999 for buildings within its scope.
BS 7974 where fire safety engineering principles are applied.
Regulation 38 requires fire safety information to be handed over for applicable building work. This information supports the Responsible Person in understanding, operating and maintaining the building safely, and undertaking an effective FRA. A fire strategy can form an important part of that information, alongside drawings, system details and other records.
There is no blanket rule that every premises must hold a separately titled fire strategy report. The necessary documentation depends on the building, the work and the applicable requirements. However, uncertainty about how a building’s fire safety measures work together should be addressed.
BSI is developing BS 9994, a new standard concerning fire strategies. Its public consultation closed in August 2026, and it remains under development. It should not yet be presented as a final published standard or a new legal requirement.
The draft reviewed proposes a more consistent approach to developing, recording, validating and maintaining fire strategies. Several themes are particularly relevant to building owners and fire risk assessors.
A strategy should remain useful throughout the building’s life. The draft treats it as an ongoing reference for design, construction, occupation and subsequent changes.
Actual occupancy and management matter. Strategies should reflect the people using the building, including their vulnerabilities, and realistic assumptions about staffing, maintenance and emergency response.
Assumptions and limitations should be clear. Readers need to understand what has been verified, where information is incomplete and which arrangements depend on management action.
Existing buildings need a proportionate approach. The draft includes guidance on in-occupation strategies, using the building’s actual condition and operation to establish a practical approach to fire safety.
Competence and validation need attention. The depth of technical work and review should reflect the building’s complexity. Validation should consider whether the strategy can achieve its objectives and be understood and implemented by those responsible.
Strategies and FRAs should inform each other. The draft reinforces the role of the strategy in supporting assessment, while recognising that an FRA serves a distinct purpose.
These proposals could help close a familiar gap: buildings having fire safety documents that are individually detailed but poorly connected. The draft recommendations may change before publication.
A fire strategy provides a clear explanation of how the building’s fire safety arrangements are intended to work. The FRA examines the risks and whether the precautions remain adequate in practice.
Their value depends on accurate information, competent judgement and action by those managing the premises.
Before your next FRA, make the current fire strategy, relevant drawings and supporting records available to the assessor. Where information is missing or no longer reflects the building, raise this early so the need for further investigation or strategy work can be properly considered.